User Tools

Site Tools


en:datasheets:smartaqm

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:smartaqm [2024-03-26 13:35] jesadminen:datasheets:smartaqm [2025-03-19 21:46] (current) – old revision restored (2025-03-19 21:43) jesadmin
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
 +[[this>doku.php?id=en:datasheets:smartaqm&do=export_pdf&tpl=datasheet_en&book_title=JES smart/AQM Data Sheet|PDF]]
  
 {{ :media:smartaqm:smartaqm_3gas_front.png?nolink&600 |}} {{ :media:smartaqm:smartaqm_3gas_front.png?nolink&600 |}}
Line 7: Line 8:
 ====== JES smart/AQM Air Quality Monitor ====== ====== JES smart/AQM Air Quality Monitor ======
  
-<columns 100% 33% 33% ->+<columns 100% 33% 33%>
  
 ===== Features ===== ===== Features =====
Line 13: Line 14:
   * Smart IoT-enabled combined visibility and gas sensor   * Smart IoT-enabled combined visibility and gas sensor
   * Scattered light visibility sensor with dual beam method   * Scattered light visibility sensor with dual beam method
-  * Dust concentration measurement with gravimetric calibration+  * Reliable early detection of fires through cold smoke detection((no smoke detector in the sense of EN 54-7 Fire detection and fire alarm systems - Part 7: Smoke detectors - Point-type smoke detectors using the scattered light, transmitted light or ionisation principle)) 
 +  * Dust concentration measurement after gravimetric calibration possible
   * Optional up to 3 electrochemical gas sensor modules (CO, NO, NO<sub>2</sub>, SO<sub>2</sub>)   * Optional up to 3 electrochemical gas sensor modules (CO, NO, NO<sub>2</sub>, SO<sub>2</sub>)
   * Installation in-situ (in the tunnel’s driving area) or with suction line up to 10 m   * Installation in-situ (in the tunnel’s driving area) or with suction line up to 10 m
Line 29: Line 31:
   * Optional smart/HUB IoT operating and control unit with touch display   * Optional smart/HUB IoT operating and control unit with touch display
   * Plug & play operation   * Plug & play operation
- 
  
 ===== System ===== ===== System =====
 +
  
   * smart/AQM sensor to be mounted either   * smart/AQM sensor to be mounted either
Line 39: Line 41:
   * System cable with quick connectors between sensor and terminal box for quick and easy sensor exchange   * System cable with quick connectors between sensor and terminal box for quick and easy sensor exchange
   * Optional smart/HUB with touch display   * Optional smart/HUB with touch display
 +
  
 <newcolumn> <newcolumn>
 +
 +
 ===== Operation ===== ===== Operation =====
  
Line 71: Line 76:
  
  
-~~SNIPPET_O1711460125~~en:snippets:datasheet:application~~+~~SNIPPET_O1752368871~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 87: Line 92:
  
   * Visibility (extractive or in-situ)    * Visibility (extractive or in-situ) 
-  * Toxic gases like CO, NO, NO2 (extractive or in-situ)+  * Toxic gases like CO, NO, NO<sub>2</sub> (extractive or in-situ)
   * Air velocity, direction and temperature   * Air velocity, direction and temperature
   * Luminance (access, threshold and interior zone)   * Luminance (access, threshold and interior zone)
Line 104: Line 109:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:aqm:aqm-basic~~+~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm-basic~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor device smart/AQM (Basic variant) !colspan="3"|Sensor device smart/AQM (Basic variant)
Line 175: Line 180:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:aqm:aqm-std~~+~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm-std~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor device smart/AQM (Standard and Smart variant) !colspan="3"|Sensor device smart/AQM (Standard and Smart variant)
Line 258: Line 263:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:aqm:aqm-tbx~~+~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm-tbx~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Terminal box - smart/AQM-TBX !colspan="3"|Terminal box - smart/AQM-TBX
Line 321: Line 326:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:ecs:ecs-co-500~~+~~SNIPPET_O1752368871~~en:snippets:techdata:ecs:ecs-co-500~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module CO-500 !colspan="3"|Gas sensor module CO-500
Line 327: Line 332:
 |Type  |Type 
 |smart/ECS-CO-500  |smart/ECS-CO-500 
-|class="image" rowspan="14"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}+|class="image" rowspan="16"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}
 |- |-
 |Measuring method |Measuring method
Line 342: Line 347:
 |- |-
 |Lower detectable limit |Lower detectable limit
-|ppm CO+|< 0.5 ppm CO
 |- |-
 |Resolution |Resolution
Line 358: Line 363:
 |Long term drift |Long term drift
 |< 2 % signal loss per month  |< 2 % signal loss per month 
 +|-
 +|Dimensions
 +|∅ 38 x 74 mm
 +|-
 +|Weight
 +|88 g
 |- |-
 |Expected operation life |Expected operation life
Line 375: Line 386:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:ecs:ecs-no2-2~~+~~SNIPPET_O1752368871~~en:snippets:techdata:ecs:ecs-no2-2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO2-2 !colspan="3"|Gas sensor module NO2-2
Line 381: Line 392:
 |Type  |Type 
 |smart/ECS-NO2-2  |smart/ECS-NO2-2 
-|class="image" rowspan="14"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}+|class="image" rowspan="16"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}
 |- |-
 |Measuring method |Measuring method
Line 412: Line 423:
 |Long term drift |Long term drift
 |< 2 % signal loss per month  |< 2 % signal loss per month 
 +|-
 +|Dimensions
 +|∅ 38 x 74 mm
 +|-
 +|Weight
 +|88 g
 |- |-
 |Expected operation life |Expected operation life
Line 428: Line 445:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:ecs:ecs-no2-20~~+~~SNIPPET_O1752368871~~en:snippets:techdata:ecs:ecs-no2-20~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO2-20 !colspan="3"|Gas sensor module NO2-20
Line 434: Line 451:
 |Type  |Type 
 |smart/ECS-NO2-20  |smart/ECS-NO2-20 
-|class="image" rowspan="14"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}+|class="image" rowspan="16"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}
 |- |-
 |Measuring method |Measuring method
Line 449: Line 466:
 |- |-
 |Lower detectable limit |Lower detectable limit
-|0.ppm NO<sub>2</sub>+|0.15 ppm NO<sub>2</sub>
 |- |-
 |Resolution |Resolution
Line 465: Line 482:
 |Long term drift |Long term drift
 |< 2 % signal loss per month  |< 2 % signal loss per month 
 +|-
 +|Dimensions
 +|∅ 38 x 74 mm
 +|-
 +|Weight
 +|88 g
 |- |-
 |Expected operation life |Expected operation life
Line 482: Line 505:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:ecs:ecs-no-100~~+~~SNIPPET_O1752368871~~en:snippets:techdata:ecs:ecs-no-100~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO-100 !colspan="3"|Gas sensor module NO-100
Line 488: Line 511:
 |Type  |Type 
 |smart/ECS-NO-100  |smart/ECS-NO-100 
-|class="image" rowspan="14"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}+|class="image" rowspan="16"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}
 |- |-
 |Measuring method |Measuring method
Line 519: Line 542:
 |Long term drift |Long term drift
 |< 2 % signal loss per month  |< 2 % signal loss per month 
 +|-
 +|Dimensions
 +|∅ 38 x 74 mm
 +|-
 +|Weight
 +|88 g
 |- |-
 |Expected operation life |Expected operation life
Line 536: Line 565:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:ecs:ecs-no-25~~+~~SNIPPET_O1752368871~~en:snippets:techdata:ecs:ecs-no-25~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO-25 !colspan="3"|Gas sensor module NO-25
Line 542: Line 571:
 |Type  |Type 
 |smart/ECS-NO-25  |smart/ECS-NO-25 
-|class="image" rowspan="14"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}+|class="image" rowspan="16"|{{:media:smartecs:100094-00_gas-sensor-module_empty_asm_front1_2023-11-06.png?80|}}
 |- |-
 |Measuring method |Measuring method
Line 557: Line 586:
 |- |-
 |Lower detectable limit |Lower detectable limit
-|0.ppm NO+|0.ppm NO
 |- |-
 |Resolution |Resolution
Line 573: Line 602:
 |Long term drift |Long term drift
 |< 2 % signal loss per month  |< 2 % signal loss per month 
 +|-
 +|Dimensions
 +|∅ 38 x 74 mm
 +|-
 +|Weight
 +|88 g
 |- |-
 |Expected operation life |Expected operation life
Line 588: Line 623:
  
 <pagebreak> <pagebreak>
 +==== Probe heater ====
 +
 +
 +~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm-pht~~
 +{|class="techdata"
 +!colspan="3"|smart/AQM-PHT Probe heater option
 +|-
 +|Type 
 +|smart/AQM-PHT
 +|rowspan="9" class="image"| {{:media:smartaqm:smartaqm-pht_vertical.png?20|}}
 +|-
 +|Control 
 +|Controlled by outside temperature (if smart/AQM-TMP installed), otherwise by internal temperature (offset configurable)
 +|-
 +|Fog concentration
 +|max. 5 g/m<sup>3</sup> in saturated air
 +|-
 +|Temperature range
 +| -40 .. 60 °C
 +|-
 +|Material 
 +|Stainless steel 1.4404 (AISI 316L) 
 +|-
 +|IP rating 
 +|IP 69 
 +|-
 +|Dimensions 
 +|∅ 64 x 335 mm
 +|-
 +|Weight 
 +|Heater 1.5 kg \\ Holder 0.4 kg
 +|}
 +~~SNIPPET_C~~en:snippets:techdata:aqm:aqm-pht~~
 +
 ==== Analogue / relay output module ==== ==== Analogue / relay output module ====
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:core:core-aro~~+~~SNIPPET_O1752368871~~en:snippets:techdata:core:core-aro~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Analogue / relay output module ARO !colspan="2"|Analogue / relay output module ARO
Line 619: Line 688:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:core:core-d2~~+~~SNIPPET_O1752368871~~en:snippets:techdata:core:core-d2~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|2.4" Internal touch display D2 !colspan="2"|2.4" Internal touch display D2
Line 647: Line 716:
  
  
 +<pagebreak>
 ==== Temperature sensor option ==== ==== Temperature sensor option ====
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:aqm:aqm-tmp~~+~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm-tmp~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|smart/AQM-TMP Temperature sensor option !colspan="3"|smart/AQM-TMP Temperature sensor option
Line 668: Line 738:
 |- |-
 |IP rating  |IP rating 
-|IP 67+|IP 69 (installed in smart/AQM)
 |- |-
 |Cable length |Cable length
Line 684: Line 754:
 ~~SNIPPET_C~~en:snippets:techdata:aqm:aqm-tmp~~ ~~SNIPPET_C~~en:snippets:techdata:aqm:aqm-tmp~~
  
- 
-<pagebreak> 
  
 ==== Temperature and humidity sensor ==== ==== Temperature and humidity sensor ====
Line 691: Line 759:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:core:core-trh~~+~~SNIPPET_O1752368871~~en:snippets:techdata:core:core-trh~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Temperature and humidity sensor !colspan="3"|Temperature and humidity sensor
Line 724: Line 792:
 |} |}
 ~~SNIPPET_C~~en:snippets:techdata:core:core-trh~~ ~~SNIPPET_C~~en:snippets:techdata:core:core-trh~~
 +
 +<pagebreak>
  
 ==== Conformities ==== ==== Conformities ====
Line 729: Line 799:
  
  
-~~SNIPPET_O1711460125~~en:snippets:techdata:aqm:aqm_conformities~~+~~SNIPPET_O1752368871~~en:snippets:techdata:aqm:aqm_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities !colspan="2"|Conformities
Line 745: Line 815:
 |- |-
 |Tunnel safety standards |Tunnel safety standards
-|AT: RVS 09.02.22 \\ +|Austria: RVS 09.02.22 \\ 
-DE: RABT 2006 \\ +Germany: RABT 2006 \\ 
-CH: ASTRA RL 13001, Fachhandbuch BSA \\ +Schweiz: ASTRA 13001 Lüftung der Strassentunnel (2021)ASTRA 13004 Branddetektion in Strassentunneln (2007), ASTRA 23001 Fachhandbuch Betriebs- und Sicherheitsausrüstungen  \\ 
-NO: Norwegian Public Roads Administration Handbook No. 021 Road Tunnels+Norway: Norwegian Public Roads Administration Handbook No. 021 Road Tunnels \\ 
 +International: ISO 23431 Measurement of road tunnel air quality
 |- |-
 |Gas monitoring |Gas monitoring
-|EN 50545-1 \\ +|Europe: EN 50545-1 \\ 
-ATÖNORM M9418, ÖNORM M9419 \\ +Austria: ÖNORM M9419 \\ 
-DE: VDI 2053+Germany: VDI 2053
 |} |}