Line 2: Line 2:
 [[this>doku.php?id=en:datasheets:smartaqm&do=export_pdf&tpl=datasheet_en&book_title=JES smart/AQM Data Sheet|PDF]] [[this>doku.php?id=en:datasheets:smartaqm&do=export_pdf&tpl=datasheet_en&book_title=JES smart/AQM Data Sheet|PDF]]
  
-{{ :media:smartaqm:smartaqm_3gas_front.png?nolink&600 |}}+{{ media:smartaqm:smartaqm_3gas_front.png?nolink&600 |}}
  
 <pagebreak> <pagebreak>
Line 8: Line 8:
 ====== JES smart/AQM Air Quality Monitor ====== ====== JES smart/AQM Air Quality Monitor ======
  
-<columns 100% 33% 33% ->+<columns 100% 33% 33%>
  
 ===== Features ===== ===== Features =====
Line 27: Line 27:
     * MODBUS/TCP (Ethernet)     * MODBUS/TCP (Ethernet)
     * Analogue and relay outputs     * Analogue and relay outputs
-    * JSON Web service (Ethernet) 
   * Integrated web server for visualisation, configuration, data logging, remote maintenance((only Standard and Smart variant))   * Integrated web server for visualisation, configuration, data logging, remote maintenance((only Standard and Smart variant))
   * Optional smart/HUB IoT operating and control unit with touch display   * Optional smart/HUB IoT operating and control unit with touch display
Line 76: Line 75:
  
  
-~~SNIPPET_O1736935778~~en:snippets:datasheet:application~~+~~SNIPPET_O1788987517~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 109: Line 108:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm-basic~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm-basic~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor device smart/AQM (Basic variant) !colspan="3"|Sensor device smart/AQM (Basic variant)
Line 130: Line 129:
 |- |-
 |Measuring range |Measuring range
-|Configurable typically 0 .. 15 / km+|Configurabletypically 0 .. 15 / km
 |- |-
 |Resolution |Resolution
Line 160: Line 159:
 |- |-
 |Analogue/relay outputs (standard)  |Analogue/relay outputs (standard) 
-|3 x 4 – 20 mA (2-wire, active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)+|3 x 4 – 20 mA (active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)
 |- |-
 |Temperature range  |Temperature range 
Line 180: Line 179:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm-std~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm-std~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor device smart/AQM (Standard and Smart variant) !colspan="3"|Sensor device smart/AQM (Standard and Smart variant)
Line 237: Line 236:
 |- |-
 |Analogue/relay outputs (standard)  |Analogue/relay outputs (standard) 
-|3 x 4 – 20 mA (2-wire, active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)+|3 x 4 – 20 mA (active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)
 |- |-
 |Additional analogue/relay outputs (optional)  |Additional analogue/relay outputs (optional) 
-|up to 2 [[#analogue/relay output module|analogue / relay output modules]], each: \\ 3 x 4 – 20 mA (2-wire, active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)+|up to 2 [[#analogue/relay output module|analogue / relay output modules]], each: \\ 3 x 4 – 20 mA (active) \\ 3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)
  
 |- |-
Line 263: Line 262:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm-tbx~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm-tbx~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Terminal box - smart/AQM-TBX !colspan="3"|Terminal box - smart/AQM-TBX
Line 326: Line 325:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:ecs:ecs-co-500~~+~~SNIPPET_O1788987517~~en:snippets:techdata:ecs:ecs-co-500~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module CO-500 !colspan="3"|Gas sensor module CO-500
Line 386: Line 385:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:ecs:ecs-no2-2~~+~~SNIPPET_O1788987517~~en:snippets:techdata:ecs:ecs-no2-2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO2-2 !colspan="3"|Gas sensor module NO2-2
Line 431: Line 430:
 |- |-
 |Expected operation life |Expected operation life
-|years in air+|years in air
 |- |-
 |Storage life |Storage life
Line 445: Line 444:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:ecs:ecs-no2-20~~+~~SNIPPET_O1788987517~~en:snippets:techdata:ecs:ecs-no2-20~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO2-20 !colspan="3"|Gas sensor module NO2-20
Line 490: Line 489:
 |- |-
 |Expected operation life |Expected operation life
-|years in air+|years in air
 |- |-
 |Storage life |Storage life
Line 505: Line 504:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:ecs:ecs-no-100~~+~~SNIPPET_O1788987517~~en:snippets:techdata:ecs:ecs-no-100~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO-100 !colspan="3"|Gas sensor module NO-100
Line 565: Line 564:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:ecs:ecs-no-25~~+~~SNIPPET_O1788987517~~en:snippets:techdata:ecs:ecs-no-25~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Gas sensor module NO-25 !colspan="3"|Gas sensor module NO-25
Line 626: Line 625:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm-pht~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm-pht~~
 {|class="techdata" {|class="techdata"
-!colspan="3"|smart/AQM-PHT Probe heater option+!colspan="3"|smart/AQM-PHT Probe heater
 |- |-
 |Type  |Type 
Line 660: Line 659:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:core:core-aro~~+~~SNIPPET_O1788987517~~en:snippets:techdata:core:core-aro~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Analogue / relay output module ARO !colspan="2"|Analogue / relay output module ARO
Line 671: Line 670:
 |- |-
 |Analogue output type |Analogue output type
-|2-wire, active +|active
 |- |-
 |Relay outputs |Relay outputs
Line 688: Line 687:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:core:core-d2~~+~~SNIPPET_O1788987517~~en:snippets:techdata:core:core-d2~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|2.4" Internal touch display D2 !colspan="2"|2.4" Internal touch display D2
Line 720: Line 719:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm-tmp~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm-tmp~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|smart/AQM-TMP Temperature sensor option !colspan="3"|smart/AQM-TMP Temperature sensor option
Line 759: Line 758:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:core:core-trh~~+~~SNIPPET_O1788987517~~en:snippets:techdata:core:core-trh~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Temperature and humidity sensor !colspan="3"|Temperature and humidity sensor
Line 799: Line 798:
  
  
-~~SNIPPET_O1736935778~~en:snippets:techdata:aqm:aqm_conformities~~+~~SNIPPET_O1788987517~~en:snippets:techdata:aqm:aqm_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities !colspan="2"|Conformities
Line 812: Line 811:
 EN IEC 61000-6-3:2007 + A1: 2011 Emission standard for residential, commercial and light-industrial environments \\ EN IEC 61000-6-3:2007 + A1: 2011 Emission standard for residential, commercial and light-industrial environments \\
 EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use \\ EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use \\
-EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements+EN IEC 61326-1:2021 Electrical equipment for measurement, control and laboratory use - EMC requirements
 |- |-
 |Tunnel safety standards |Tunnel safety standards
en/datasheets/smartaqm.1736935778.txt.gz · Last modified: (external edit)