User Tools

Site Tools


en:datasheets:smartflow-dp

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:smartflow-dp [2025-03-31 13:50] – [Merkmale] jesadminen:datasheets:smartflow-dp [2025-06-23 19:57] (current) – external edit 127.0.0.1
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
-[[this>doku.php?id=en:datasheets:smartflow-dp&do=export_pdf&tpl=datasheet_de&book_title=JES smart/FLOW-DP Data Sheet|PDF]]+[[this>doku.php?id=en:datasheets:smartflow-dp&do=export_pdf&tpl=datasheet_en&book_title=JES smart/FLOW-DP Data Sheet|PDF]]
 {{ :media:smartflow-dp:tfl-dp_front.png?nolink&400 |}} {{ :media:smartflow-dp:tfl-dp_front.png?nolink&400 |}}
  
Line 45: Line 45:
 <newcolumn> <newcolumn>
  
-===== Features =====+===== Operation =====
  
 When measuring air flow using the differential pressure method, the air flow is measured at 2 points in the tunnel cross-section. The method allows the electronic components to be optionally removed from the tunnel in order to maintain the measurement even at high temperatures. When measuring air flow using the differential pressure method, the air flow is measured at 2 points in the tunnel cross-section. The method allows the electronic components to be optionally removed from the tunnel in order to maintain the measurement even at high temperatures.
Line 75: Line 75:
  
  
-~~SNIPPET_O1743429056~~en:snippets:datasheet:application~~+~~SNIPPET_O1752351077~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 105: Line 105:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:smartflow-dp:smartflow-dp_airflow_measurement~~+~~SNIPPET_O1752351077~~en:snippets:techdata:smartflow-dp:smartflow-dp_airflow_measurement~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Air flow measurement !colspan="2"|Air flow measurement
Line 119: Line 119:
 |- |-
 |Measuring range  |Measuring range 
-| -20 ... 20 m/s+| -20 ... 20 m/s 
 |- |-
 |Resolution  |Resolution 
Line 133: Line 133:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:smartflow-dp:smartflow-dp-sr~~+~~SNIPPET_O1752351077~~en:snippets:techdata:smartflow-dp:smartflow-dp-sr~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor  !colspan="3"|Sensor 
Line 183: Line 183:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:hub:hub-std~~+~~SNIPPET_O1752351077~~en:snippets:techdata:hub:hub-std~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|IoT gateway, data logger and control unit smart/HUB !colspan="3"|IoT gateway, data logger and control unit smart/HUB
Line 237: Line 237:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:hub:hub-d2~~+~~SNIPPET_O1752351077~~en:snippets:techdata:hub:hub-d2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|IoT gateway, data logger and control unit smart/HUB-D2 !colspan="3"|IoT gateway, data logger and control unit smart/HUB-D2
Line 304: Line 304:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:hub:hub-485~~+~~SNIPPET_O1752351077~~en:snippets:techdata:hub:hub-485~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|4 x RS-485 extension !colspan="2"|4 x RS-485 extension
Line 346: Line 346:
  
  
-~~SNIPPET_O1743429056~~en:snippets:techdata:core:core-d7~~+~~SNIPPET_O1752351077~~en:snippets:techdata:core:core-d7~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|7" External touch display smart/CORE-D7 !colspan="3"|7" External touch display smart/CORE-D7
en/datasheets/smartflow-dp.1743429055.txt.gz · Last modified: by jesadmin