User Tools

Site Tools


en:datasheets:smartflow-dp

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en:datasheets:smartflow-dp [2025-03-31 14:02] jesadminen:datasheets:smartflow-dp [2025-06-23 19:57] (current) – external edit 127.0.0.1
Line 75: Line 75:
  
  
-~~SNIPPET_O1743429734~~en:snippets:datasheet:application~~+~~SNIPPET_O1752350977~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 105: Line 105:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:smartflow-dp:smartflow-dp_airflow_measurement~~+~~SNIPPET_O1752350977~~en:snippets:techdata:smartflow-dp:smartflow-dp_airflow_measurement~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Air flow measurement !colspan="2"|Air flow measurement
Line 119: Line 119:
 |- |-
 |Measuring range  |Measuring range 
-| -20 ... 20 m/s+| -20 ... 20 m/s 
 |- |-
 |Resolution  |Resolution 
Line 133: Line 133:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:smartflow-dp:smartflow-dp-sr~~+~~SNIPPET_O1752350977~~en:snippets:techdata:smartflow-dp:smartflow-dp-sr~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Sensor  !colspan="3"|Sensor 
Line 183: Line 183:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:hub:hub-std~~+~~SNIPPET_O1752350977~~en:snippets:techdata:hub:hub-std~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|IoT gateway, data logger and control unit smart/HUB !colspan="3"|IoT gateway, data logger and control unit smart/HUB
Line 237: Line 237:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:hub:hub-d2~~+~~SNIPPET_O1752350977~~en:snippets:techdata:hub:hub-d2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|IoT gateway, data logger and control unit smart/HUB-D2 !colspan="3"|IoT gateway, data logger and control unit smart/HUB-D2
Line 304: Line 304:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:hub:hub-485~~+~~SNIPPET_O1752350977~~en:snippets:techdata:hub:hub-485~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|4 x RS-485 extension !colspan="2"|4 x RS-485 extension
Line 346: Line 346:
  
  
-~~SNIPPET_O1743429734~~en:snippets:techdata:core:core-d7~~+~~SNIPPET_O1752350977~~en:snippets:techdata:core:core-d7~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|7" External touch display smart/CORE-D7 !colspan="3"|7" External touch display smart/CORE-D7
en/datasheets/smartflow-dp.1743429733.txt.gz · Last modified: by jesadmin