User Tools

Site Tools


en:datasheets:tfl-usx

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:tfl-usx [2024-02-28 21:46] – [Application] jesadminen:datasheets:tfl-usx [2024-08-07 18:47] (current) jesadmin
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
 +[[this>doku.php?id=en:datasheets:tfl-usx&do=export_pdf&tpl=datasheet_en&book_title=JES t/FL-USX Data Sheet|PDF]]
 +
 {{ :media:tfl-usx:d-fl220t.png?nolink&600 | t/FL-USX Air Flow Monitoring System}} {{ :media:tfl-usx:d-fl220t.png?nolink&600 | t/FL-USX Air Flow Monitoring System}}
 <pagebreak> <pagebreak>
-====== JES t/FL-USX Air Flow Monitoring System ======+====== JES t/FL-USX Ultrasonic Cross Section Air Flow Monitoring System ======
  
 <columns 100% 33% 33% -> <columns 100% 33% 33% ->
Line 8: Line 10:
 ===== Features ===== ===== Features =====
  
-  *Precise ultrasonic air flow measuring system based on different transition times of ul-trasonic pulses+  *Precise ultrasonic air flow measuring system based on different transition times of ultrasonic pulses
   *Measurement of average air-flow over the whole tunnel cross section   *Measurement of average air-flow over the whole tunnel cross section
-  *Sensor setup via service inter-face +  *Sensor setup via service interface 
-  *Suitable for tunnel cross sec-tions up to 18 m \\(Measuring path up to 25 m)+  *Suitable for tunnel cross sections up to 18 m \\ (Measuring path up to 25 m)
   *Connection to tunnel control system either via analogue output and relays or via RS 485 MODBUS RTU   *Connection to tunnel control system either via analogue output and relays or via RS 485 MODBUS RTU
-  *Visible LEDs to indicate sen-sor status +  *Visible LEDs to indicate sensor status 
-  *Optional, remote touch opera-tion unit to display measured values and to modify parame-ters+  *Optional, remote smart/HUB touch operation unit to display measured values and to modify parameters
  
 ===== System setup ===== ===== System setup =====
- 
   *Two sensors (master & slave) with mounting clamps mount-ed below the tunnel ceiling in an angle of 30° to 60° to the tunnel axis   *Two sensors (master & slave) with mounting clamps mount-ed below the tunnel ceiling in an angle of 30° to 60° to the tunnel axis
   *Terminal box for master to connect the power supply and the connections to the tunnel control system and the slave   *Terminal box for master to connect the power supply and the connections to the tunnel control system and the slave
   *Terminal box for Slave   *Terminal box for Slave
-  *Optional remote touch operat-ing unit+  *Optional remote smart/HUB touch operating unit
  
 <newcolumn> <newcolumn>
Line 49: Line 50:
 ===== Application ===== ===== Application =====
  
-~~SNIPPET_O1709156789~~en:snippets:datasheet:application~~+~~SNIPPET_O1752351561~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 65: Line 66:
  
   * Visibility (extractive or in-situ)    * Visibility (extractive or in-situ) 
-  * Toxic gases like CO, NO, NO2 (extractive or in-situ)+  * Toxic gases like CO, NO, NO<sub>2</sub> (extractive or in-situ)
   * Air velocity, direction and temperature   * Air velocity, direction and temperature
   * Luminance (access, threshold and interior zone)   * Luminance (access, threshold and interior zone)
Line 136: Line 137:
 ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx_outputs~~ ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx_outputs~~
  
 +<pagebreak>
 ==== Ultrasonic transceiver (sensor) ==== ==== Ultrasonic transceiver (sensor) ====
  
Line 192: Line 194:
 ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:d-fl220tm~~ ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:d-fl220tm~~
  
 +
 +<pagebreak>
  
 ==== t/FL-USX-TBX terminal boxes ==== ==== t/FL-USX-TBX terminal boxes ====
Line 309: Line 313:
 ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx-tbx-b~~ ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx-tbx-b~~
  
 +
 +<pagebreak>
  
 ==== smart/BOX-S-FL-USX gateway (instead of t/FL-USX-TBX-A for Ethernet connection) ==== ==== smart/BOX-S-FL-USX gateway (instead of t/FL-USX-TBX-A for Ethernet connection) ====
Line 379: Line 385:
 ==== Conformities ==== ==== Conformities ====
  
-~~SNIPPET_O1709155386~~en:snippets:techdata:tfl-usx:tfl-usx_conformities~~+~~SNIPPET_O1752351561~~en:snippets:techdata:tfl-usx:tfl-usx_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities !colspan="2"|Conformities
Line 393: Line 399:
 |- |-
 |Tunnel safety standards |Tunnel safety standards
-|AT: RVS 09.02.22 \\ +|Austria: RVS 09.02.22 \\ 
-DE: RABT 2006 \\ +Germany: RABT 2006 \\ 
-CH: ASTRA RL 13001, Fachhandbuch BSA \\ +Switzerland: ASTRA RL 13001, Fachhandbuch BSA \\ 
-NO: Norwegian Public Roads Administration Handbook No. 021 Road Tunnels+Norway: Norwegian Public Roads Administration Handbook No. 021 Road Tunnels \\ 
 +International: ISO 23431 Measurement of road tunnel air quality
 |} |}
 ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx_conformities~~ ~~SNIPPET_C~~en:snippets:techdata:tfl-usx:tfl-usx_conformities~~
  
en/datasheets/tfl-usx.1709156789.txt.gz · Last modified: by jesadmin