en:datasheets:tlum
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:datasheets:tlum [2024-07-01 22:37] – jesadmin | en:datasheets:tlum [2024-09-24 11:48] (current) – jesadmin | ||
---|---|---|---|
Line 1: | Line 1: | ||
~~NOTOC~~ | ~~NOTOC~~ | ||
+ | [[this> | ||
{{ : | {{ : | ||
Line 16: | Line 17: | ||
*Interior zone L< | *Interior zone L< | ||
*Zoom lens to adjust the focus areas | *Zoom lens to adjust the focus areas | ||
- | *Sensor with V(λ) filter and sili-con | + | *Sensor with V(λ) filter and silicon |
*Temperature compensated and long term stable amplifier for the photoelectric current using live zero | *Temperature compensated and long term stable amplifier for the photoelectric current using live zero | ||
- | *Heated housing with protec-tion | + | *Heated housing with protection |
- | *Electronically controlled | + | *Electronically controlled |
- | *Mounting flange to adjust | + | *Mounting flange to adjust |
- | *Fault indication by relay isolat-ed | + | *Fault indication by relay contact (NC) |
- | *Optional second output | + | *Optional second output |
*Surge protection | *Surge protection | ||
Line 40: | Line 41: | ||
The requirements for tunnel lighting are determined by the nature of the human eye. How well the eye recognises vehicles and other obstacles in a tunnel depends on the lighting and visibility as well as the reflexion characteristics of the road surface and the tunnel walls. Tunnel lighting needs to be adapted to these environmental conditions. | The requirements for tunnel lighting are determined by the nature of the human eye. How well the eye recognises vehicles and other obstacles in a tunnel depends on the lighting and visibility as well as the reflexion characteristics of the road surface and the tunnel walls. Tunnel lighting needs to be adapted to these environmental conditions. | ||
- | The tunnel lighting must be controlled such that users, both during the day and by night, can approach, pass through and exit the tunnel without changing direction or speed with a degree of safety equal to that on the approach road. Especially the lighting of a tunnel entrance should be adequate to avoid the “black hole effect” when a driver enters the tunnel. | + | |
- | Luminance is the measure representing what a human being perceives as brightness and as such is the main control variable for the tunnel lighting. | + | The tunnel lighting must be controlled such that users, both during the day and by night, can approach, pass through and exit the tunnel without changing direction or speed with a degree of safety equal to that on the approach road. Especially the lighting of a tunnel entrance should be adequate to avoid the “black hole effect” when a driver enters the tunnel. Luminance is the measure representing what a human being perceives as brightness and as such is the main control variable for the tunnel lighting. |
The luminance photometer comes with a zoom lens that is focussed to measure the relevant area. Light from this area through the lens is directed to the photo element de-tecting its intensity. The integrated evaluation unit then calculates the luminance and provides it through the analogue output(s) | The luminance photometer comes with a zoom lens that is focussed to measure the relevant area. Light from this area through the lens is directed to the photo element de-tecting its intensity. The integrated evaluation unit then calculates the luminance and provides it through the analogue output(s) | ||
Line 86: | Line 88: | ||
{{: | {{: | ||
- | < | ||
===== Technical Specifications ===== | ===== Technical Specifications ===== | ||
Line 94: | Line 95: | ||
- | ~~SNIPPET_O1719873476~~en: | + | ~~SNIPPET_O1752334052~~en: |
{|class=" | {|class=" | ||
!colspan=" | !colspan=" | ||
Line 114: | Line 115: | ||
|Power consumption ||approx. 50 W | |Power consumption ||approx. 50 W | ||
|- | |- | ||
- | |Overvoltage protection | + | |Overvoltage protection |
|- | |- | ||
- | |Dimensions | + | |Dimensions |
|- | |- | ||
- | |Protection class ||IP 67 | + | |IP rating |
|- | |- | ||
- | |Materials | + | |Materials |
|- | |- | ||
- | |Weight | + | |Weight |
|- | |- | ||
|Temperature range ||-40°C ... +70°C | |Temperature range ||-40°C ... +70°C | ||
|} | |} | ||
- | * currently not available | ||
~~SNIPPET_C~~en: | ~~SNIPPET_C~~en: | ||
Line 132: | Line 132: | ||
- | ~~SNIPPET_O1719873476~~en: | + | ~~SNIPPET_O1752334052~~en: |
{|class=" | {|class=" | ||
!colspan=" | !colspan=" | ||
Line 154: | Line 154: | ||
|Power consumption ||approx. 50 W | |Power consumption ||approx. 50 W | ||
|- | |- | ||
- | |Overvoltage protection | + | |Overvoltage protection |
|- | |- | ||
- | |Dimensions | + | |Dimensions |
|- | |- | ||
- | |Protection class ||IP 67 | + | |IP rating ||IP 67 |
|- | |- | ||
- | |Materials | + | |Materials |
|- | |- | ||
- | |Weight | + | |Weight |
|- | |- | ||
|Temperature range ||-40°C ... +70°C | |Temperature range ||-40°C ... +70°C | ||
|} | |} | ||
- | * currently not available | ||
~~SNIPPET_C~~en: | ~~SNIPPET_C~~en: | ||
==== Conformities ==== | ==== Conformities ==== | ||
- | ~~SNIPPET_O1719873476~~en: | + | ~~SNIPPET_O1752334052~~en: |
{|class=" | {|class=" | ||
!colspan=" | !colspan=" |
en/datasheets/tlum.1719873476.txt.gz · Last modified: by jesadmin