User Tools

Site Tools


en:datasheets:tlum

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:tlum [2024-07-01 22:37] jesadminen:datasheets:tlum [2024-09-24 11:48] (current) jesadmin
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
 +[[this>doku.php?id=en:datasheets:tlum&do=export_pdf&tpl=datasheet_en&book_title=JES t/LUM Data Sheet|PDF]]
  
 {{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}} {{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}}
Line 16: Line 17:
     *Interior zone L<sub>in</sub>     *Interior zone L<sub>in</sub>
   *Zoom lens to adjust the focus areas   *Zoom lens to adjust the focus areas
-  *Sensor with V(λ) filter and sili-con photo element+  *Sensor with V(λ) filter and silicon photo element
   *Temperature compensated and long term stable amplifier for the photoelectric current using live zero   *Temperature compensated and long term stable amplifier for the photoelectric current using live zero
-  *Heated housing with protec-tion class IP65 either made of polycarbonate or stainless steel 1.4571 +  *Heated housing with protection class IP67 made of stainless steel 1.4404 or polycarbonate (optional) 
-  *Electronically controlled heat-ing and temperature monitoring +  *Electronically controlled heating and temperature monitoring 
-  *Mounting flange to adjust hori-zontal and vertical angle +  *Mounting flange to adjust horizontal and vertical angle 
-  *Fault indication by relay isolat-ed contact (NC) +  *Fault indication by relay contact (NC) 
-  *Optional second output chan-nel for increased resolution at low lighting levels+  *Optional second output channel for increased resolution at low lighting levels
   *Surge protection   *Surge protection
  
Line 40: Line 41:
  
 The requirements for tunnel lighting are determined by the nature of the human eye. How well the eye recognises vehicles and other obstacles in a tunnel depends on the lighting and visibility as well as the reflexion characteristics of the road surface and the tunnel walls. Tunnel lighting needs to be adapted to these environmental conditions. The requirements for tunnel lighting are determined by the nature of the human eye. How well the eye recognises vehicles and other obstacles in a tunnel depends on the lighting and visibility as well as the reflexion characteristics of the road surface and the tunnel walls. Tunnel lighting needs to be adapted to these environmental conditions.
-The tunnel lighting must be controlled such that users, both during the day and by night, can approach, pass through and exit the tunnel without changing direction or speed with a degree of safety equal to that on the approach road. Especially the lighting of a tunnel entrance should be adequate to avoid the “black hole effect” when a driver enters the tunnel. + 
-Luminance is the measure representing what a human being perceives as brightness and as such is the main control variable for the tunnel lighting.+The tunnel lighting must be controlled such that users, both during the day and by night, can approach, pass through and exit the tunnel without changing direction or speed with a degree of safety equal to that on the approach road. Especially the lighting of a tunnel entrance should be adequate to avoid the “black hole effect” when a driver enters the tunnel. Luminance is the measure representing what a human being perceives as brightness and as such is the main control variable for the tunnel lighting. 
 The luminance photometer comes with a zoom lens that is focussed to measure the relevant area. Light from this area through the lens is directed to the photo element de-tecting its intensity. The integrated evaluation unit then calculates the luminance and provides it through the analogue output(s) The luminance photometer comes with a zoom lens that is focussed to measure the relevant area. Light from this area through the lens is directed to the photo element de-tecting its intensity. The integrated evaluation unit then calculates the luminance and provides it through the analogue output(s)
  
Line 86: Line 88:
 {{:media:tlum:tlum_zones.png?600|}} {{:media:tlum:tlum_zones.png?600|}}
  
-<pagebreak> 
  
 ===== Technical Specifications ===== ===== Technical Specifications =====
Line 94: Line 95:
  
  
-~~SNIPPET_O1719873476~~en:snippets:techdata:lum:lum-a1~~+~~SNIPPET_O1752334052~~en:snippets:techdata:lum:lum-a1~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Luminance meter with 1 analogue output !colspan="3"|Luminance meter with 1 analogue output
Line 114: Line 115:
 |Power consumption ||approx. 50 W |Power consumption ||approx. 50 W
 |- |-
-|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (meassurand output)+|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (analogue output)
 |- |-
-|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>\\ without mounting flange +|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange 
 |- |-
-|Protection class ||IP 67 +|IP rating              ||IP 67 
 |- |-
-|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>\\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II+|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II
 |- |-
-|Weight                 ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg+|Weight                 ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg
 |- |-
 |Temperature range      ||-40°C ... +70°C  |Temperature range      ||-40°C ... +70°C 
 |} |}
-* currently not available 
 ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~ ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~
  
Line 132: Line 132:
  
  
-~~SNIPPET_O1719873476~~en:snippets:techdata:lum:lum-a2~~+~~SNIPPET_O1752334052~~en:snippets:techdata:lum:lum-a2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Luminance meter with 2 analogue outputs !colspan="3"|Luminance meter with 2 analogue outputs
Line 154: Line 154:
 |Power consumption ||approx. 50 W |Power consumption ||approx. 50 W
 |- |-
-|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (meassurand output)+|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (analogue output)
 |- |-
-|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>\\ without mounting flange +|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange
 |- |-
-|Protection class ||IP 67 +|IP rating ||IP 67 
 |- |-
-|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>\\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II+|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II
 |- |-
-|Weight                 ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg+|Weight                 ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg
 |- |-
 |Temperature range      ||-40°C ... +70°C  |Temperature range      ||-40°C ... +70°C 
 |} |}
-* currently not available 
 ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~ ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~
  
 ==== Conformities ==== ==== Conformities ====
  
-~~SNIPPET_O1719873476~~en:snippets:techdata:lum:lum_conformities~~+~~SNIPPET_O1752334052~~en:snippets:techdata:lum:lum_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities and applied standards !colspan="2"|Conformities and applied standards
en/datasheets/tlum.1719873476.txt.gz · Last modified: by jesadmin