User Tools

Site Tools


en:datasheets:tlum

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:tlum [2024-07-02 07:34] – [Operation] jesadminen:datasheets:tlum [2024-09-24 11:48] (current) jesadmin
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
 +[[this>doku.php?id=en:datasheets:tlum&do=export_pdf&tpl=datasheet_en&book_title=JES t/LUM Data Sheet|PDF]]
  
 {{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}} {{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}}
Line 18: Line 19:
   *Sensor with V(λ) filter and silicon photo element   *Sensor with V(λ) filter and silicon photo element
   *Temperature compensated and long term stable amplifier for the photoelectric current using live zero   *Temperature compensated and long term stable amplifier for the photoelectric current using live zero
-  *Heated housing with protection class IP65 either made of polycarbonate or stainless steel 1.4571+  *Heated housing with protection class IP67 made of stainless steel 1.4404 or polycarbonate (optional)
   *Electronically controlled heating and temperature monitoring   *Electronically controlled heating and temperature monitoring
   *Mounting flange to adjust horizontal and vertical angle   *Mounting flange to adjust horizontal and vertical angle
-  *Fault indication by relay isolated contact (NC)+  *Fault indication by relay contact (NC)
   *Optional second output channel for increased resolution at low lighting levels   *Optional second output channel for increased resolution at low lighting levels
   *Surge protection   *Surge protection
Line 87: Line 88:
 {{:media:tlum:tlum_zones.png?600|}} {{:media:tlum:tlum_zones.png?600|}}
  
-<pagebreak> 
  
 ===== Technical Specifications ===== ===== Technical Specifications =====
Line 95: Line 95:
  
  
-~~SNIPPET_O1719905653~~en:snippets:techdata:lum:lum-a1~~+~~SNIPPET_O1752335119~~en:snippets:techdata:lum:lum-a1~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Luminance meter with 1 analogue output !colspan="3"|Luminance meter with 1 analogue output
Line 115: Line 115:
 |Power consumption ||approx. 50 W |Power consumption ||approx. 50 W
 |- |-
-|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (meassurand output)+|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (analogue output)
 |- |-
-|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>\\ without mounting flange +|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange 
 |- |-
-|Protection class ||IP 67 +|IP rating              ||IP 67 
 |- |-
-|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>\\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II+|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II
 |- |-
-|Weight                 ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg+|Weight                 ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg
 |- |-
 |Temperature range      ||-40°C ... +70°C  |Temperature range      ||-40°C ... +70°C 
 |} |}
-* currently not available 
 ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~ ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~
  
Line 133: Line 132:
  
  
-~~SNIPPET_O1719905653~~en:snippets:techdata:lum:lum-a2~~+~~SNIPPET_O1752335119~~en:snippets:techdata:lum:lum-a2~~
 {|class="techdata" {|class="techdata"
 !colspan="3"|Luminance meter with 2 analogue outputs !colspan="3"|Luminance meter with 2 analogue outputs
Line 155: Line 154:
 |Power consumption ||approx. 50 W |Power consumption ||approx. 50 W
 |- |-
-|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (meassurand output)+|Overvoltage protection  ||varistors (mains) \\ surge arrestor and varistors (analogue output)
 |- |-
-|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>\\ without mounting flange +|Dimensions         ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange
 |- |-
-|Protection class ||IP 67 +|IP rating ||IP 67 
 |- |-
-|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>\\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II+|Materials              ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II
 |- |-
-|Weight                 ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg+|Weight                 ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg
 |- |-
 |Temperature range      ||-40°C ... +70°C  |Temperature range      ||-40°C ... +70°C 
 |} |}
-* currently not available 
 ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~ ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~
  
 ==== Conformities ==== ==== Conformities ====
  
-~~SNIPPET_O1719905653~~en:snippets:techdata:lum:lum_conformities~~+~~SNIPPET_O1752335119~~en:snippets:techdata:lum:lum_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities and applied standards !colspan="2"|Conformities and applied standards
en/datasheets/tlum.1719905653.txt.gz · Last modified: by jesadmin