| [[this>doku.php?id=en:datasheets:tlum&do=export_pdf&tpl=datasheet_en&book_title=JES t/LUM Data Sheet|PDF]] |
| |
{{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}} | {{ :media:tlum:tlum_edelstahl.jpg?nolink&600 |}} |
*Electronically controlled heating and temperature monitoring | *Electronically controlled heating and temperature monitoring |
*Mounting flange to adjust horizontal and vertical angle | *Mounting flange to adjust horizontal and vertical angle |
*Fault indication by relay isolated contact (NC) | *Fault indication by relay contact (NC) |
*Optional second output channel for increased resolution at low lighting levels | *Optional second output channel for increased resolution at low lighting levels |
*Surge protection | *Surge protection |
| |
| |
===== System setup ===== | ===== System ===== |
| |
| |
| |
| |
~~SNIPPET_O1720016427~~en:snippets:techdata:lum:lum-a1~~ | ~~SNIPPET_O1752335626~~en:snippets:techdata:lum:lum-a1~~ |
{|class="techdata" | {|class="techdata" |
!colspan="3"|Luminance meter with 1 analogue output | !colspan="3"|Luminance meter with 1 analogue output |
|Overvoltage protection ||varistors (mains) \\ surge arrestor and varistors (analogue output) | |Overvoltage protection ||varistors (mains) \\ surge arrestor and varistors (analogue output) |
|- | |- |
|Dimensions ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>* \\ without mounting flange | |Dimensions ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange |
|- | |- |
|IP rating ||IP 67 | |IP rating ||IP 67 |
|- | |- |
|Materials ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>* \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II | |Materials ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II |
|- | |- |
|Weight ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg | |Weight ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg |
|- | |- |
|Temperature range ||-40°C ... +70°C | |Temperature range ||-40°C ... +70°C |
|} | |} |
* currently not available | |
~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~ | ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a1~~ |
| |
| |
| |
~~SNIPPET_O1720016427~~en:snippets:techdata:lum:lum-a2~~ | ~~SNIPPET_O1752335626~~en:snippets:techdata:lum:lum-a2~~ |
{|class="techdata" | {|class="techdata" |
!colspan="3"|Luminance meter with 2 analogue outputs | !colspan="3"|Luminance meter with 2 analogue outputs |
|Overvoltage protection ||varistors (mains) \\ surge arrestor and varistors (analogue output) | |Overvoltage protection ||varistors (mains) \\ surge arrestor and varistors (analogue output) |
|- | |- |
|Dimensions ||180 x 180 x 445 mm (stainless steel) \\ <del>245 x 180 x 485 mm (polycarbonate)</del>* \\ without mounting flange | |Dimensions ||180 x 180 x 445 mm (stainless steel) \\ 245 x 180 x 485 mm (polycarbonate) \\ without mounting flange |
|- | |- |
|IP rating ||IP 67 | |IP rating ||IP 67 |
|- | |- |
|Materials ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ <del>Polycarbonate MAKROTECH UV®</del>* \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II | |Materials ||Stainless steel 1.4404 (AISI 316L) or 1.4571 (AISI 316Ti) \\ Polycarbonate MAKROTECH UV® (on request if Class II appliance is required) \\ ZTV-ING Anforderungsklasse I (all of the above) \\ \\ Custom-made: Stainless steel 1.4547 (AISI 254SMO) \\ ZTV-ING Anforderungsklasse II |
|- | |- |
|Weight ||Luminance meter: 9.6 kg (stainless steel) \\ Mounting console: 4.0 kg | |Weight ||Luminance meter: 9.6 kg (stainless steel), 6.2 kg (polycarbonate) \\ Mounting console: 4.0 kg |
|- | |- |
|Temperature range ||-40°C ... +70°C | |Temperature range ||-40°C ... +70°C |
|} | |} |
* currently not available | |
~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~ | ~~SNIPPET_C~~en:snippets:techdata:lum:lum-a2~~ |
| |
==== Conformities ==== | ==== Conformities ==== |
| |
~~SNIPPET_O1720016427~~en:snippets:techdata:lum:lum_conformities~~ | ~~SNIPPET_O1752335626~~en:snippets:techdata:lum:lum_conformities~~ |
{|class="techdata" | {|class="techdata" |
!colspan="2"|Conformities and applied standards | !colspan="2"|Conformities and applied standards |