User Tools

Site Tools


en:datasheets:tlux

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
en:datasheets:tlux [2024-08-06 12:14] – [Operation] jes_alexaueren:datasheets:tlux [2024-09-24 11:48] (current) jesadmin
Line 1: Line 1:
 ~~NOTOC~~ ~~NOTOC~~
 +[[this>doku.php?id=en:datasheets:tlux&do=export_pdf&tpl=datasheet_en&book_title=JES t/LUX Data Sheet|PDF]]
  
 {{ media:tlux:tlux_device.png?300 |}} {{ media:tlux:tlux_device.png?300 |}}
Line 11: Line 12:
 ===== Features ===== ===== Features =====
  
-  * Photometer to measure the illu-minance at the mounting point of the sensor+  * Photometer to measure the illuminance at the mounting point of the sensor
   * Cosine correction   * Cosine correction
   * V(λ) adaptation   * V(λ) adaptation
Line 40: Line 41:
 ===== Advantanges ===== ===== Advantanges =====
  
 +  * Specifically designed for application in tunnels 
 +  * Customisable measuring range 
 +  * Resistant against corrosion, UV, oil and acid
  
 <newcolumn> <newcolumn>
 ===== Application ===== ===== Application =====
  
 +
 +~~SNIPPET_O1752351609~~en:snippets:datasheet:application~~
 +Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
 +
 +Environmental conditions in tunnels are influenced by fog, particles and emissions and need to be monitored to protect people on their passage through the tunnel from danger and impacts on their health. Accidents in tunnels, and particularly fires, can have dramatic consequences and can prove extremely costly in terms of human life, increased congestion, pollution and repair costs. At every time people in the tunnel need to be supplied with breathable air and sufficient visibility.
 +
 +Since 1990 JES Elektrotechnik GmbH develops, installs and maintains systems to monitor air characteristics and lighting conditions in tunnels. Our systems are robust, durable and resistant against the corrosive atmosphere in a tunnel. They operate reliably and have a high accuracy in measurement. 
 +
 +All systems fulfil the requirements of the EC guideline 2004/54/EC (Minimum safety requirements for tunnels in the trans-European road network) and the more detailed national guidelines and provisions:
 +
 +  * Austria: RVS 09.02 Tunnelausrüstung
 +  * Germany: RABT Richtlinien für die Ausstattung und den Betrieb von Straßentunneln
 +  * Switzerland: ASTRA Richtlinien und Fachhandbuch Betriebs- und Sicherheitsausrüstungen (BSA)
 +
 +Our range of products for tunnel covers systems for monitoring of
 +
 +  * Visibility (extractive or in-situ) 
 +  * Toxic gases like CO, NO, NO<sub>2</sub> (extractive or in-situ)
 +  * Air velocity, direction and temperature
 +  * Luminance (access, threshold and interior zone)
 +  * Illuminance
 +~~SNIPPET_C~~en:snippets:datasheet:application~~
  
  
Line 53: Line 78:
 ===== Technical Specifications ===== ===== Technical Specifications =====
  
-====== -#2 Technical data ====== 
  
 +~~SNIPPET_O1752351609~~en:snippets:techdata:tlux:tlux_techdata~~
 <table> <table>
 {|class="techdata" {|class="techdata"
Line 85: Line 110:
 |} |}
 </table> </table>
 +~~SNIPPET_C~~en:snippets:techdata:tlux:tlux_techdata~~
  
 +
 +~~SNIPPET_O1752351609~~en:snippets:techdata:tlux:tlux~~
 <table> <table>
 {|class="techdata” {|class="techdata”
-!colspan="2"|Illuminance sensor+!colspan="3"|Illuminance meter
 |- |-
-|Name+|Name (Type)
 |t/LUX |t/LUX
 +|rowspan="17" class="image"|{{:media:tlux:tlux_device.png?200|}}
 |- |-
 |Power supply |Power supply
Line 113: Line 142:
 |} |}
 </table> </table>
 +~~SNIPPET_C~~en:snippets:techdata:tlux:tlux~~
  
 +
 +~~SNIPPET_O1752351609~~en:snippets:techdata:tlux:tluxh~~
 <table> <table>
 {|class="techdata" {|class="techdata"
-!colspan="2"|Illuminance sensor heated housing+!colspan="3"|Illuminance sensor heated housing
 |- |-
 |Name |Name
 |t/LUX-H |t/LUX-H
 +|rowspan="17" class="image"|{{:media:tlux:tluxh_device.png?200|}}
 |- |-
 |Power supply |Power supply
Line 125: Line 158:
 |- |-
 |Heating |Heating
-|100 W (controlled by thermostat))+|100 W (controlled by thermostat)
 |- |-
 |Material |Material
Line 133: Line 166:
 | -40°C bis +60°C | -40°C bis +60°C
 |- |-
-|Protection class+|IP rating
 |IP 65 |IP 65
 |- |-
Line 144: Line 177:
 |} |}
 </table> </table>
 +~~SNIPPET_C~~en:snippets:techdata:tlux:tluxh~~
  
 +
 +~~SNIPPET_O1752351609~~en:snippets:techdata:tlux:tlux_outputs~~
 <table> <table>
 {|class="techdata” {|class="techdata”
Line 154: Line 190:
 |} |}
 </table> </table>
 +~~SNIPPET_C~~en:snippets:techdata:tlux:tlux_outputs~~
  
  
 +~~SNIPPET_O1752351609~~en:snippets:techdata:tlux:tlux_conformities~~
 <table> <table>
 {|class="techdata” {|class="techdata”
Line 172: Line 210:
 |} |}
 </table> </table>
 +~~SNIPPET_C~~en:snippets:techdata:tlux:tlux_conformities~~
 +
 +
en/datasheets/tlux.1722946478.txt.gz · Last modified: by jes_alexauer