en:datasheets:tsig-d
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:datasheets:tsig-d [2024-09-24 10:14] – [Funktion] jesadmin | en:datasheets:tsig-d [2024-10-15 11:45] (current) – jes_alex | ||
---|---|---|---|
Line 1: | Line 1: | ||
~~NOTOC~~ | ~~NOTOC~~ | ||
+ | [[this> | ||
- | {{ : | + | {{ : |
< | < | ||
Line 33: | Line 34: | ||
===== Function===== | ===== Function===== | ||
- | Traffic lights in tunnels are essential for influencing traffic in the event of hazards or accidents. The status of such traffic lights must be monitored to ensure tunnel safety. A traffic light in the tunnel is usually controlled by the tunnel control system. It is connected to the signal monitoring device via conventional PLC inputs and outputs. The traffic light controller switches the corresponding | + | Traffic lights in tunnels are essential for influencing traffic in the event of hazards or accidents. The status of such traffic lights must be monitored to ensure tunnel safety. A traffic light in the tunnel is usually controlled by the tunnel control system. It is connected to the signal monitoring device via conventional PLC inputs and outputs. The traffic light controller switches the signals (red, yellow, green) on and off as given by the outputs of the tunnel control system and reports back the status of the traffic light. In the event of faults such as broken wires or a defective light source, an error message is issued |
- | ===== Vorteile | + | ===== Advantages |
- | * Speziell für die Anwendung vor und in Tunnels entwickelt | + | * Specially designed for use in front of and in tunnels |
- | * Montage auf DIN-Hutschiene zum einfachen Einbau und Tausch | + | * Mounting on DIN rail for easy installation and replacement |
- | * Für Glühlampen und LED-Technik geeignet | + | * Suitable for conventional lamps and LED technology |
- | * Display | + | * Display |
- | * Ein Gerät zur Überwachung von bis zu zwei Verkehrslichtsignalgebern | + | * One device for monitoring up to two traffic lights |
- | * Vor Ort Steuerung über ein Touchdisplay | + | * On-site control via a touch display |
- | * Frei konfigurierbare Fehler- oder Betriebsmeldungen über Webserver | + | * Freely configurable error or operating messages via web server |
- | * Ruhestromüberwachung der Leuchteinsätze | + | * Monitoring of signals both in switched-on and switched-off state |
< | < | ||
===== Application ===== | ===== Application ===== | ||
- | ~~SNIPPET_O1727172845~~en: | + | ~~SNIPPET_O1752351659~~en: |
Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. | Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. | ||
Line 78: | Line 79: | ||
< | < | ||
- | ===== Technische Daten ===== | + | ===== Technical specifications |
- | ~~SNIPPET_O1719206784~~de: | + | |
+ | ~~SNIPPET_O1752351659~~en: | ||
+ | {| class=" | ||
+ | !colspan=" | ||
+ | |- | ||
+ | |Traffic lights | ||
+ | |Up to 2, can be controlled together or separately | ||
+ | |- | ||
+ | |Signals | ||
+ | |1-, 2- or 3-signal traffic lights configurable | ||
+ | |- | ||
+ | |Flashing lights | ||
+ | |must be implemented outside traffic light controller | ||
+ | |- | ||
+ | |Supported luminaires | ||
+ | |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W | ||
+ | |- | ||
+ | |Reduction of brightness at night / alternative voltage supply for traffic lights | ||
+ | |alternative voltage input | ||
+ | |- | ||
+ | |Active signal fault | ||
+ | |< 50 % of configured nominal current | ||
+ | |- | ||
+ | |Inactive signal fault | ||
+ | |> 30 mA OR > 3 V vs. N | ||
+ | |} | ||
+ | ~~SNIPPET_C~~en: | ||
+ | |||
+ | |||
+ | |||
+ | ~~SNIPPET_O1752351659~~en: | ||
{|class=" | {|class=" | ||
- | !colspan=" | + | !colspan=" |
|- | |- | ||
- | |Bezeichnung | + | |Type |
|t/SIG-D | |t/SIG-D | ||
|- | |- | ||
- | |Betriebsspannung | + | |Operating voltage |
|24 VDC ± 10 % | |24 VDC ± 10 % | ||
|- | |- | ||
- | |Stromaufnahme | + | |Current consumption |
- | |max. 150 mA (Steuerteil) | + | |max. 150 mA (controller only) |
|- | |- | ||
- | |Schutzart | + | |IP rating |
|IP20 | |IP20 | ||
|- | |- | ||
- | |Schutzklasse | + | |Appliance class |
- | |II (Schutzisolierung) | + | |II (double insulated) |
|- | |- | ||
- | |Schnittstellen | + | |Interfaces |
- | |Digitale Ein- und Ausgänge für Breite Anbindung \\ Ethernet | + | |Ethernet: MODBUS/TCP and web server for configuration |
|- | |- | ||
- | |Steuereingänge | + | |Digital inputs |
- | |(6) 1 x je Signal, 24 VDC, max. 2 mA \\ 2 x Nachtabsenkung, | + | |1 x per signal |
|- | |- | ||
- | |Stausausgänge | + | |Digital outputs |
- | |(6) 1 x je Signal bei Betrieb von zwei VLSG oder \\ 2 x je Signal optional bei Betrieb von einem VLSG 24 VDC, max. 50 mA \\ 2 x Betriebs-/Störmeldung, | + | |1 x signal status |
|- | |- | ||
- | |Montage | + | |Output rating |
- | |DIN-Hutschiene 35 mm | + | |24 VDC, max. 50 mA |
|- | |- | ||
- | |Breite | + | |Mount |
+ | |35 mm DIN rail | ||
+ | |- | ||
+ | |Width | ||
|45 mm | |45 mm | ||
|- | |- | ||
- | |Höhe | + | |Height |
|120 mm | |120 mm | ||
|- | |- | ||
- | |Tiefe | + | |Depth |
|120 mm | |120 mm | ||
|- | |- | ||
- | |Einbauraum | + | |Space requirement |
|45 x 140 x 120 mm | |45 x 140 x 120 mm | ||
|- | |- | ||
- | |Gewicht | + | |Weight |
|300 g | |300 g | ||
|} | |} | ||
- | ~~SNIPPET_C~~de: | + | ~~SNIPPET_C~~en: |
- | |||
- | ~~SNIPPET_O1719206784~~de: | ||
- | {| class=" | ||
- | !colspan=" | ||
- | mit Glühlampen oder LED-Einsätzen | ||
- | |- | ||
- | |Signalgeber | ||
- | |Bis zu 2, gemeinsam oder getrennt ansteuerbar | ||
- | |- | ||
- | |Signale | ||
- | |1-, 2- oder 3-begriffige Signalgeber frei konfigurierbar | ||
- | |- | ||
- | |Blinktakt | ||
- | |Muss extern generiert werden | ||
- | |- | ||
- | |Unterstützte Leuchtmittel | ||
- | |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W | ||
- | |- | ||
- | |Nachtabsenkung / zweite Helligkeitsstufe | ||
- | |Über zweite (niedrigere) Versorgungsspannung | ||
- | |- | ||
- | |Arbeitsstromfehler | ||
- | |< 50 % des konfigurierten Nennstroms | ||
- | |- | ||
- | |Ruhestromfehler | ||
- | |> 30 mA oder > 3 V gegen N | ||
- | |} | ||
- | ~~SNIPPET_C~~de: | ||
< | < | ||
- | ===== Konformitäten | + | ===== Conformities |
- | ~~SNIPPET_O1719206784~~de: | + | ~~SNIPPET_O1752351659~~en: |
{|class=" | {|class=" | ||
- | !colspan=" | + | !colspan=" |
+ | |- | ||
+ | |Markings | ||
+ | |{{: | ||
|- | |- | ||
- | |Elektrische Normen | + | |Electrical standards |
- | |2014/ | + | |2014/ |
- | 2014/ | + | 2014/ |
- | EN IEC 61000-6-2:2005 Störfestigkeit für Industriebereiche | + | EN IEC 61000-6-2:2019 Immunity standard for industrial environments |
- | EN IEC 61000-6-3: | + | EN IEC 61000-6-3: |
|} | |} | ||
- | ~~SNIPPET_C~~de: | + | ~~SNIPPET_C~~en: |
en/datasheets/tsig-d.1727172845.txt.gz · Last modified: by jesadmin