en:datasheets:tsig-d
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
en:datasheets:tsig-d [2024-09-24 11:25] – [Technische Daten] jesadmin | en:datasheets:tsig-d [2024-10-15 11:45] (current) – jes_alex | ||
---|---|---|---|
Line 1: | Line 1: | ||
~~NOTOC~~ | ~~NOTOC~~ | ||
+ | [[this> | ||
- | {{ : | + | {{ : |
< | < | ||
Line 51: | Line 52: | ||
===== Application ===== | ===== Application ===== | ||
- | ~~SNIPPET_O1727177102~~en: | + | ~~SNIPPET_O1752351424~~en: |
Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. | Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. | ||
Line 78: | Line 79: | ||
< | < | ||
- | ===== Technische Daten ===== | + | ===== Technical specifications |
- | ~~SNIPPET_O1727177102~~en: | + | ~~SNIPPET_O1752351424~~en: |
+ | {| class=" | ||
+ | !colspan=" | ||
+ | |- | ||
+ | |Traffic lights | ||
+ | |Up to 2, can be controlled together or separately | ||
+ | |- | ||
+ | |Signals | ||
+ | |1-, 2- or 3-signal traffic lights configurable | ||
+ | |- | ||
+ | |Flashing lights | ||
+ | |must be implemented outside traffic light controller | ||
+ | |- | ||
+ | |Supported luminaires | ||
+ | |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W | ||
+ | |- | ||
+ | |Reduction of brightness at night / alternative voltage supply for traffic lights | ||
+ | |alternative voltage input | ||
+ | |- | ||
+ | |Active signal fault | ||
+ | |< 50 % of configured nominal current | ||
+ | |- | ||
+ | |Inactive signal fault | ||
+ | |> 30 mA OR > 3 V vs. N | ||
+ | |} | ||
+ | ~~SNIPPET_C~~en: | ||
+ | |||
+ | |||
+ | |||
+ | ~~SNIPPET_O1752351424~~en: | ||
{|class=" | {|class=" | ||
!colspan=" | !colspan=" | ||
Line 102: | Line 132: | ||
|- | |- | ||
|Interfaces | |Interfaces | ||
- | |Ethernet: MODBUS/TCP and web server for configuration \\ RS485 MODBUS-RTU | + | |Ethernet: MODBUS/TCP and web server for configuration \\ RS485 MODBUS RTU |
|- | |- | ||
|Digital inputs | |Digital inputs | ||
Line 133: | Line 163: | ||
~~SNIPPET_C~~en: | ~~SNIPPET_C~~en: | ||
- | |||
- | ~~SNIPPET_O1719206784~~de: | ||
- | {| class=" | ||
- | !colspan=" | ||
- | mit Glühlampen oder LED-Einsätzen | ||
- | |- | ||
- | |Signalgeber | ||
- | |Bis zu 2, gemeinsam oder getrennt ansteuerbar | ||
- | |- | ||
- | |Signale | ||
- | |1-, 2- oder 3-begriffige Signalgeber frei konfigurierbar | ||
- | |- | ||
- | |Blinktakt | ||
- | |Muss extern generiert werden | ||
- | |- | ||
- | |Unterstützte Leuchtmittel | ||
- | |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W | ||
- | |- | ||
- | |Nachtabsenkung / zweite Helligkeitsstufe | ||
- | |Über zweite (niedrigere) Versorgungsspannung | ||
- | |- | ||
- | |Arbeitsstromfehler | ||
- | |< 50 % des konfigurierten Nennstroms | ||
- | |- | ||
- | |Ruhestromfehler | ||
- | |> 30 mA oder > 3 V gegen N | ||
- | |} | ||
- | ~~SNIPPET_C~~de: | ||
< | < | ||
- | ===== Konformitäten | + | ===== Conformities |
- | ~~SNIPPET_O1719206784~~de: | + | ~~SNIPPET_O1752351424~~en: |
{|class=" | {|class=" | ||
- | !colspan=" | + | !colspan=" |
+ | |- | ||
+ | |Markings | ||
+ | |{{: | ||
|- | |- | ||
- | |Elektrische Normen | + | |Electrical standards |
- | |2014/ | + | |2014/ |
- | 2014/ | + | 2014/ |
- | EN IEC 61000-6-2:2005 Störfestigkeit für Industriebereiche | + | EN IEC 61000-6-2:2019 Immunity standard for industrial environments |
- | EN IEC 61000-6-3: | + | EN IEC 61000-6-3: |
|} | |} | ||
- | ~~SNIPPET_C~~de: | + | ~~SNIPPET_C~~en: |
en/datasheets/tsig-d.1727177102.txt.gz · Last modified: by jesadmin