User Tools

Site Tools


en:datasheets:tsig-d

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
en:datasheets:tsig-d [2024-10-15 11:28] jes_alexen:datasheets:tsig-d [2024-10-15 11:45] (current) jes_alex
Line 21: Line 21:
     * Digital inputs/outputs     * Digital inputs/outputs
     * MODBUS/TCP     * MODBUS/TCP
-    * MODBUS/RTU+    * MODBUS RTU
   * Touch display in the front panel for signalling the traffic light status and for manual switching on site    * Touch display in the front panel for signalling the traffic light status and for manual switching on site 
   * 35 mm DIN rail mount   * 35 mm DIN rail mount
Line 52: Line 52:
 ===== Application ===== ===== Application =====
  
-~~SNIPPET_O1728991730~~en:snippets:datasheet:application~~+~~SNIPPET_O1752351184~~en:snippets:datasheet:application~~
 Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.  Tunnels are important infrastructure elements in road networks and facilitate the connection of regions. 
  
Line 83: Line 83:
  
  
-~~SNIPPET_O1728991730~~en:snippets:techdata:tsig-d:tsig-d_signals~~+~~SNIPPET_O1752351184~~en:snippets:techdata:tsig-d:tsig-d_signals~~
 {| class="techdata" {| class="techdata"
 !colspan="2"|Monitoring of traffic lights with conventional lamps or LED inserts !colspan="2"|Monitoring of traffic lights with conventional lamps or LED inserts
Line 91: Line 91:
 |- |-
 |Signals |Signals
-|1-, 2- oder 3-signal traffic lights configurable+|1-, 2- or 3-signal traffic lights configurable
 |- |-
 |Flashing lights |Flashing lights
Line 99: Line 99:
 |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W |0 - 230 VAC, 60 Hz, max. 100 W \\ 0 - 60 VDC, max. 30 W
 |- |-
-|Reduction of brightness at night / alternate voltage supply for traffic lights +|Reduction of brightness at night / alternative voltage supply for traffic lights 
-|alternate voltage input+|alternative voltage input
 |- |-
 |Active signal fault |Active signal fault
Line 112: Line 112:
  
  
-~~SNIPPET_O1728991730~~en:snippets:techdata:tsig-d:tsig-d_device~~+~~SNIPPET_O1752351184~~en:snippets:techdata:tsig-d:tsig-d_device~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Traffic signal controller !colspan="2"|Traffic signal controller
Line 132: Line 132:
 |- |-
 |Interfaces |Interfaces
-|Ethernet: MODBUS/TCP and web server for configuration \\ RS485 MODBUS-RTU+|Ethernet: MODBUS/TCP and web server for configuration \\ RS485 MODBUS RTU
 |- |-
 |Digital inputs |Digital inputs
Line 169: Line 169:
  
  
-~~SNIPPET_O1728991730~~en:snippets:techdata:tsig-d:tsig-d_conformities~~+~~SNIPPET_O1752351184~~en:snippets:techdata:tsig-d:tsig-d_conformities~~
 {|class="techdata" {|class="techdata"
 !colspan="2"|Conformities !colspan="2"|Conformities
en/datasheets/tsig-d.1728991730.txt.gz · Last modified: by jes_alex