User Tools

Site Tools


en:datasheets:smartecs
This is an old revision of the document. It contains one or more snippets which may be outdated.
Replace outdated snippets in this Old Revision?Yes No



JES smart/ECS Multi Gas Sensor

Features

  • Smart IoT enabled gas sensor
  • Up to 4 electrochemical gas sensor modules (CO, NO, NO2, SO2)
  • Installation in-situ (in the tunnel’s driving area) or with suction line adapter
  • Stainless steel housing 1.4404 (AISI 316L)
  • IP rating IP69K
  • Connection to tunnel control system by
    • MODBUS RTU (RS-485)
    • MODBUS/TCP (Ethernet)
    • Analogue and relay outputs
    • JSON Web service (Ethernet)
  • Integrated web server for visualisation, configuration, data logging, remote maintenance (Ethernet option only)
  • Optional smart/HUB IoT operating and control unit with touch display
  • Plug & play operation

System setup

  • smart/ECS sensor to be mounted either
    • in-situ (directly in the tunnel’s driving area) or
    • extractive in a niche, cross-cut, etc.
  • Optional smart/HUB with touch display

Operation

Gas monitoring during normal operation is used to control the tunnel ventilation at normal operation. If and with how much power artificial ventilation by jet fans is operated depends on the measured visibility and gas concentration. Electrochemical gas sensor cells induce currents proportional to the prevailing gas concentration. With these currents and the measured temperature, the gas sensor modules calculate the gas concentrations.

Advantanges

  • Specifically designed for application in tunnels
  • Single sensor instead of transmitter/receiver pair requiring exact alignment
  • Low maintenance requirements, stable, accurate
  • Pre-calibrated gas sensor modules for easy exchange
  • Smart IoT enabled solution from sensor over hub to asset management
  • Condition monitoring
  • Remote maintenance
  • Flexible integration into tunnel control system

Application

Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.

Environmental conditions in tunnels are influenced by fog, particles and emissions and need to be monitored to protect people on their passage through the tunnel from danger and impacts on their health. Accidents in tunnels, and particularly fires, can have dramatic consequences and can prove extremely costly in terms of human life, increased congestion, pollution and repair costs. At every time people in the tunnel need to be supplied with breathable air and sufficient visibility.

Since 1990 JES Elektrotechnik GmbH develops, installs and maintains systems to monitor air characteristics and lighting conditions in tunnels. Our systems are robust, durable and resistant against the corrosive atmosphere in a tunnel. They operate reliably and have a high accuracy in measurement.

All systems fulfil the requirements of the EC guideline 2004/54/EC (Minimum safety requirements for tunnels in the trans-European road network) and the more detailed national guidelines and provisions:

  • Austria: RVS 09.02 Tunnelausrüstung
  • Germany: RABT Richtlinien für die Ausstattung und den Betrieb von Straßentunneln
  • Switzerland: ASTRA Richtlinien und Fachhandbuch Betriebs- und Sicherheitsausrüstungen (BSA)

Our range of products for tunnel covers systems for monitoring of

  • Visibility (extractive or in-situ)
  • Toxic gases like CO, NO, NO2 (extractive or in-situ)
  • Air velocity, direction and temperature
  • Luminance (access, threshold and interior zone)
  • Illuminance


Technical Specifications

Sensor device

Sensor device smart/ECS (Standard variant)
Type JES smart/ECS
Gas sensor ports up to 3 (to be specified on order)
Power supply 24 VDC ± 10 %
Current consumption max. 300 mA (@ 24 VDC)
Appliance class Class III (PELV)
Material Stainless steel 1.4404 (AISI 316L)
IP rating IP 69K
Dimensions 160 x 160 x 100 mm
Weight Approx. 2.5 Kg
Digital interfaces
(standard)
MODBUS RTU (RS-485)
MODBUS/TCP (Ethernet)
Webserver for configuration (Ethernet)
Analogue/relay outputs (optional) up to 2 analogue / relay output modules, each:
3 x 4 – 20 mA (2-wire, active)
3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)
Temperature range -40 .. +60 °C
Pressure range 900 .. 1100 hPa
Humidity range 15 .. 95% relative humidity (non-condensing)
Storage temperature -40 .. +85 °C (without gas sensor modules)

Sensor device smart/ECS-XL (XL variant)
Type JES smart/ECS-XL
Gas sensor ports up to 4 (to be specified on order)
Power supply 24 VDC ± 10 %
AC option: 100 to 240 VAC, 50/60 Hz
Current consumption max. 300 mA (@ 24 VDC)
Appliance class Class III (PELV)
Class I (AC option)
Material Stainless steel 1.4404 (AISI 316L)
IP rating IP 69K
Dimensions 250 x 160 x 100 mm
Weight Approx. 2.5 Kg
Digital interfaces
(standard)
MODBUS RTU (RS-485)
MODBUS/TCP (Ethernet)
Webserver for configuration (Ethernet)
Analogue/relay outputs (optional) up to 2 analogue / relay output modules, each:
3 x 4 – 20 mA (2-wire, active)
3 x SPST-NO (max. 60 VDC / 25 VAC, max. 0.5 A)
Temperature range -40 .. +60 °C
Pressure range 900 .. 1100 hPa
Humidity range 15 .. 95% relative humidity (non-condensing)
Storage temperature -40 .. +85 °C (without gas sensor modules)

Gas sensor modules

Gas sensor module CO-500
Type JES smart/ECS-CO-500
Measuring method Electrochemical cell
Measured value Gas concentration in ppm
Measuring range Configurable within 0 .. 500 ppm CO
typically 0 .. 300 ppm CO
Maximum overload 1,000 ppm CO
Lower detectable limit 3 ppm CO
Resolution 0.1 ppm CO
Accuracy ± 2 ppm or 2 % reading1)
Temperature compensation yes
T90 time < 40 s
Long term drift < 2 % signal loss per month
Expected operation life 3 years in air
Storage life 6 months in packaging
Storage temperature 5 .. 20 °C

Gas sensor module NO2-2
Type JES smart/ECS-NO2-2
Measuring method Electrochemical cell
Measured value Gas concentration in ppm
Measuring range Configurable within 0 .. 2 ppm NO2
typically 0 .. 2 ppm NO2
Maximum overload 10 ppm NO2
Lower detectable limit 0.05 ppm NO2
Resolution 0.02 ppm NO2
Accuracy ± 0.05 ppm or 5 % reading2)
Temperature compensation yes
T90 time < 60 s
Long term drift < 2 % signal loss per month
Expected operation life 2 years in air
Storage life 6 months in packaging
Storage temperature 5 .. 20 °C

Gas sensor module NO2-20
Type JES smart/ECS-NO2-20
Measuring method Electrochemical cell
Measured value Gas concentration in ppm
Measuring range Configurable within 0 .. 20 ppm NO2
typically 0 .. 10 ppm NO2
Maximum overload 200 ppm NO2
Lower detectable limit 0.5 ppm NO2
Resolution 0.05 ppm NO2
Accuracy ± 0.5 ppm or 2 % reading3)
Temperature compensation yes
T90 time < 60 s
Long term drift < 2 % signal loss per month
Expected operation life 2 years in air
Storage life 6 months in packaging
Storage temperature 5 .. 20 °C

Gas sensor module NO-100
Type JES smart/ECS-NO-100
Measuring method Electrochemical cell
Measured value Gas concentration in ppm
Measuring range Configurable within 0 .. 100 ppm NO
typically 0 .. 30 ppm NO
Maximum overload 200 ppm NO
Lower detectable limit 1 ppm NO
Resolution 0.05 ppm NO
Accuracy ± 0.5 ppm or 2 % reading4)
Temperature compensation yes
T90 time < 10 s
Long term drift < 2 % signal loss per month
Expected operation life 3 years in air
Storage life 6 months in packaging
Storage temperature 5 .. 20 °C

Gas sensor module NO-25
Type JES smart/ECS-NO-25
Measuring method Electrochemical cell
Measured value Gas concentration in ppm
Measuring range Configurable within 0 .. 25 ppm NO
overload up to 0 .. 30 ppm NO
Maximum overload 50 ppm NO
Lower detectable limit 0.2 ppm NO
Resolution 0.05 ppm NO
Accuracy ± 0.2 ppm or 2 % reading5)
Temperature compensation yes
T90 time < 10 s
Long term drift < 2 % signal loss per month
Expected operation life 3 years in air
Storage life 6 months in packaging
Storage temperature 5 .. 20 °C

Analogue / relay output module

Analogue / relay output module ARO
Type JES smart/CORE-ARO
Analogue outputs 3 x 4 - 20 mA
Analogue output type 2-wire, active
Relay outputs 3 x SPST-NO
Max. contact rating max. 60 VDC / 25 VAC, max. 0.5 A

2.4" Touch display

2.4“ Internal touch display D2
Type JES smart/CORE-D2
Display type TFT colour
Diagonal screen size 2.4” (60.96 mm)
Display area 49.96 x 37.72 mm
Resolution 320 x 240 px
Touch type capacitive
Backlight LED - white

Temperature Sensor

smart/ECS-TMP Temperature sensor option
Type JES smart/ECS-TMP
Temperature sensor Pt1000 DIN B, R0: 1000 Ω, Temperature coefficient: 3.850 x 10-3/°C, Standard: DIN EN 60751
Sensor sleeve material Stainless steel 1.4571 (AISI 316Ti)
Cable material Silicon
IP rating IP 67
Cable length 30 cm (longer on request)
Temperature range -60 .. +180 °C
Humidity range 5 .. 95% relative humidity (non-condensing)
Storage temperature -30 .. +70 °C

Conformities

Conformities
Electrical standards 2014/35/EU Low Voltage Directive (LVD)
2014/30/EU Electromagnetic compatibility (EMC)
EN IEC 61000-6-2:2019 Immunity standard for industrial environments
EN IEC 61000-6-3:2007 + A1: 2011 Emission standard for residential, commercial and light-industrial environments
EN 61010-1 Safety requirements for electrical equipment for measurement, control and laboratory use
EN 61326-1 Electrical equipment for measurement, control and laboratory use - EMC requirements
Tunnel safety standards AT: RVS 09.02.22
DE: RABT 2006
CH: ASTRA RL 13001, Fachhandbuch BSA
NO: Norwegian Public Roads Administration Handbook No. 021 Road Tunnels
Gas monitoring EN 50545-1
AT: ÖNORM M9418, ÖNORM M9419
DE: VDI 2053

Document Revision

1) , 2) , 3) , 4) , 5)
whichever is greater
en/datasheets/smartecs.1699131708.txt.gz · Last modified: by jesadmin