JES t/LUX Illuminance Meter
FeaturesSystem |
OperationAdvantanges |
Application |
Technical Specifications
2. Technical data
Illuminance measurement | |
---|---|
Measured value | Illuminance |
Measuring range | Selectable, typically 0 .. 200 lx |
Measurement accuracy | ± 3% (5 to 200 lx) ± 6% (at 1 lx) not defined for measured values below 1 lx |
Zero point drift | 0.02 lx / °C |
Reference temperature | 20°C |
Spectral range of photosensitivity | Adjusted by V-Lambda filter Vrel(λ) ≥ 80% between 490 nm and 630 nm |
Directional characteristic | Half ellipse, Erel = 0.8 at ± 35° |
Illuminance meter | |
---|---|
Name (Type) | t/LUX |
Power supply | 24 VDC via current loop |
Housing material | Glass bead reinforced polyamide (PA 6 30% GK) |
Temperature range | -25 °C to +60 °C |
IP rating | IP 65 |
Dimensions | 64 x 98 x 34 mm |
Weight | 300 g |
Outputs | |
---|---|
Analogue output | 1 x 4-20 mA, 2-wire, passive |
Conformities | |
---|---|
Electrical engineering | 2006/95/EC Low Voltage Directive (LVD) 2004/108/EC Electromagnetic compatibility (EMC) IEC 61326-1:2012 IEC 61010-1:2010 |
Tunnel safety | AT: RVS 09.02.41 DE: RABT 2006, DIN 67542-2 |