JES t/LUX Illuminance Meter

Features

System

Operation

Advantanges

Application


Technical Specifications

2. Technical data

Illuminance measurement
Measured value Illuminance
Measuring range Selectable, typically 0 .. 200 lx
Measurement accuracy ± 3% (5 to 200 lx)
± 6% (at 1 lx)
not defined for measured values ​​below 1 lx
Zero point drift 0.02 lx / °C
Reference temperature 20°C
Spectral range of photosensitivity Adjusted by V-Lambda filter
Vrel(λ) ≥ 80% between 490 nm and 630 nm
Directional characteristic Half ellipse, Erel = 0.8 at ± 35°
Illuminance sensor
Name t/LUX
Power supply 24 VDC via current loop
Housing material Glass bead reinforced polyamide (PA 6 30% GK)
Temperature range -25 °C to +60 °C
IP rating IP 65
Dimensions 64 x 98 x 34 mm
Weight 300 g
Illuminance sensor heated housing
Name t/LUX-H
Power supply 230 VAC (other voltages on request)
Heating 100 W (controlled by thermostat))
Material Glass fibre reinforced polyester, RAL 7035 or Stainless steel 1.4571 (AISI 316Ti) (optionally)
Temperature range -40°C bis +60°C
Protection class IP 65
Dimensions 250 x 300 x 140 mm
Weight 4,5 kg
Outputs
Analogue output 1 x 4-20 mA, 2-wire, passive
Conformities
Electrical engineering 2006/95/EC Low Voltage Directive (LVD)
2004/108/EC Electromagnetic compatibility (EMC)
IEC 61326-1:2012
IEC 61010-1:2010
Tunnel safety AT: RVS 09.02.41
DE: RABT 2006, DIN 67542-2