JES t/SIG-D Traffic light controller

Features

  • Switching and monitoring of traffic lights
  • Up to 2 traffic lights can be switched via one device
  • 1-, 2- or 3-signal traffic lights configurable
  • Monitoring of light bulb and LED inserts both switched on and off
  • Reduced brightness at night by second supply voltage
  • Freely configurable operating/fault messages for each of the two traffic lights
  • Connection to and control by PLC via
    • Digital inputs/outputs
    • MODBUS/TCP
    • MODBUS RTU
  • Touch display in the front panel for signalling the traffic light status and for manual switching on site
  • 35 mm DIN rail mount

System

  • Traffic light controller with touch display
  • Optional transformer for providing a lower supply voltage to reduce brightness at nighttime

Funktion

Verkehrslichtsignalgeber in Tunnels sind essentiell zur Beeinflussung des Verkehrs bei Gefahren oder Unfällen. Die Zustände solcher Verkehrslichtsignalgeber müssen zur Gewährleistung der Tunnelsicherheit überwacht werden. Die Ansteuerung eines Verkehrslichtsignalgebers im Tunnel erfolgt über die Tunnelsteuerung. Sie ist über herkömmliche SPS Ein- und Ausgänge mit dem Signalüberwachungsgerät verbunden. Dieses schaltet auf Befehl der Tunnelsteuerung die entsprechenden Signale (rot, gelb, grün) ein und aus und signalisiert der Tunnelsteuerung den Betriebszustand des Verkehrslichtsignalgebers. Im Falle von Störungen wie Leitungsbruch, defektes Leuchtmittel wird eine im ein- und ausgeschalteten Zustand eine Störmeldung ausgegeben.

Vorteile

  • Speziell für die Anwendung vor und in Tunnels entwickelt
  • Montage auf DIN-Hutschiene zum einfachen Einbau und Tausch
  • Für Glühlampen und LED-Technik geeignet
  • Display zur Anzeige von Signalzustand und Störungen
  • Ein Gerät zur Überwachung von bis zu zwei Verkehrslichtsignalgebern
  • Vor Ort Steuerung über ein Touchdisplay
  • Frei konfigurierbare Fehler- oder Betriebsmeldungen über Webserver
  • Ruhestromüberwachung der Leuchteinsätze

Application

Tunnels are important infrastructure elements in road networks and facilitate the connection of regions.

Environmental conditions in tunnels are influenced by fog, particles and emissions and need to be monitored to protect people on their passage through the tunnel from danger and impacts on their health. Accidents in tunnels, and particularly fires, can have dramatic consequences and can prove extremely costly in terms of human life, increased congestion, pollution and repair costs. At every time people in the tunnel need to be supplied with breathable air and sufficient visibility.

Since 1990 JES Elektrotechnik GmbH develops, installs and maintains systems to monitor air characteristics and lighting conditions in tunnels. Our systems are robust, durable and resistant against the corrosive atmosphere in a tunnel. They operate reliably and have a high accuracy in measurement.

All systems fulfil the requirements of the EC guideline 2004/54/EC (Minimum safety requirements for tunnels in the trans-European road network) and the more detailed national guidelines and provisions:

  • Austria: RVS 09.02 Tunnelausrüstung
  • Germany: RABT Richtlinien für die Ausstattung und den Betrieb von Straßentunneln
  • Switzerland: ASTRA Richtlinien und Fachhandbuch Betriebs- und Sicherheitsausrüstungen (BSA)

Our range of products for tunnel covers systems for monitoring of

  • Visibility (extractive or in-situ)
  • Toxic gases like CO, NO, NO2 (extractive or in-situ)
  • Air velocity, direction and temperature
  • Luminance (access, threshold and interior zone)
  • Illuminance


Technische Daten

Verkehrslichtsignalgeber-Steuergerät
Bezeichnung t/SIG-D
Betriebsspannung 24 VDC ± 10 %
Stromaufnahme max. 150 mA (Steuerteil)
Schutzart IP20
Schutzklasse II (Schutzisolierung)
Schnittstellen Digitale Ein- und Ausgänge für Breite Anbindung
Ethernet für Modbus/TCP und Gerätekonfiguration
RS485 für Modbus/RTU
Steuereingänge (6) 1 x je Signal, 24 VDC, max. 2 mA
2 x Nachtabsenkung, 24 VDC, max. 2 mA
Stausausgänge (6) 1 x je Signal bei Betrieb von zwei VLSG oder
2 x je Signal optional bei Betrieb von einem VLSG 24 VDC, max. 50 mA
2 x Betriebs-/Störmeldung, 24 VDC, max. 50 mA
Montage DIN-Hutschiene 35 mm
Breite 45 mm
Höhe 120 mm
Tiefe 120 mm
Einbauraum 45 x 140 x 120 mm
Gewicht 300 g

Überwachung von Verkehrslichtsignalgebern mit Glühlampen oder LED-Einsätzen
Signalgeber Bis zu 2, gemeinsam oder getrennt ansteuerbar
Signale 1-, 2- oder 3-begriffige Signalgeber frei konfigurierbar
Blinktakt Muss extern generiert werden
Unterstützte Leuchtmittel 0 - 230 VAC, 60 Hz, max. 100 W
0 - 60 VDC, max. 30 W
Nachtabsenkung / zweite Helligkeitsstufe Über zweite (niedrigere) Versorgungsspannung
Arbeitsstromfehler < 50 % des konfigurierten Nennstroms
Ruhestromfehler > 30 mA oder > 3 V gegen N


Konformitäten

Konformitäten
Elektrische Normen 2014/35/EU Niederspannungsrichtlinie (LVD)
2014/30/EU Elektromagnetische Verträglichkeit (EMV)
EN IEC 61000-6-2:2005 Störfestigkeit für Industriebereiche
EN IEC 61000-6-3:2007 + A1: 2011 Störaussendung für Wohnbereich, Geschäfts- und Gewerbebereiche sowie Kleinbetriebe