Replace outdated snippets in this Old Revision?Yes No
JES t/SIG-D Traffic light controller
Features
System
|
FunctionTraffic lights in tunnels are essential for influencing traffic in the event of hazards or accidents. The status of such traffic lights must be monitored to ensure tunnel safety. A traffic light in the tunnel is usually controlled by the tunnel control system. It is connected to the signal monitoring device via conventional PLC inputs and outputs. The traffic light controller switches the signals (red, yellow, green) on and off as given by the outputs of the tunnel control system and reports back the status of the traffic light. In the event of faults such as broken wires or a defective light source, an error message is issued even when the respective signal is currently in switched off state. Vorteile
|
ApplicationTunnels are important infrastructure elements in road networks and facilitate the connection of regions. Environmental conditions in tunnels are influenced by fog, particles and emissions and need to be monitored to protect people on their passage through the tunnel from danger and impacts on their health. Accidents in tunnels, and particularly fires, can have dramatic consequences and can prove extremely costly in terms of human life, increased congestion, pollution and repair costs. At every time people in the tunnel need to be supplied with breathable air and sufficient visibility. Since 1990 JES Elektrotechnik GmbH develops, installs and maintains systems to monitor air characteristics and lighting conditions in tunnels. Our systems are robust, durable and resistant against the corrosive atmosphere in a tunnel. They operate reliably and have a high accuracy in measurement. All systems fulfil the requirements of the EC guideline 2004/54/EC (Minimum safety requirements for tunnels in the trans-European road network) and the more detailed national guidelines and provisions:
Our range of products for tunnel covers systems for monitoring of
|
Technische Daten
Verkehrslichtsignalgeber-Steuergerät | |
---|---|
Bezeichnung | t/SIG-D |
Betriebsspannung | 24 VDC ± 10 % |
Stromaufnahme | max. 150 mA (Steuerteil) |
Schutzart | IP20 |
Schutzklasse | II (Schutzisolierung) |
Schnittstellen | Digitale Ein- und Ausgänge für Breite Anbindung Ethernet für Modbus/TCP und Gerätekonfiguration RS485 für Modbus/RTU |
Steuereingänge | (6) 1 x je Signal, 24 VDC, max. 2 mA 2 x Nachtabsenkung, 24 VDC, max. 2 mA |
Stausausgänge | (6) 1 x je Signal bei Betrieb von zwei VLSG oder 2 x je Signal optional bei Betrieb von einem VLSG 24 VDC, max. 50 mA 2 x Betriebs-/Störmeldung, 24 VDC, max. 50 mA |
Montage | DIN-Hutschiene 35 mm |
Breite | 45 mm |
Höhe | 120 mm |
Tiefe | 120 mm |
Einbauraum | 45 x 140 x 120 mm |
Gewicht | 300 g |
Überwachung von Verkehrslichtsignalgebern mit Glühlampen oder LED-Einsätzen | |
---|---|
Signalgeber | Bis zu 2, gemeinsam oder getrennt ansteuerbar |
Signale | 1-, 2- oder 3-begriffige Signalgeber frei konfigurierbar |
Blinktakt | Muss extern generiert werden |
Unterstützte Leuchtmittel | 0 - 230 VAC, 60 Hz, max. 100 W 0 - 60 VDC, max. 30 W |
Nachtabsenkung / zweite Helligkeitsstufe | Über zweite (niedrigere) Versorgungsspannung |
Arbeitsstromfehler | < 50 % des konfigurierten Nennstroms |
Ruhestromfehler | > 30 mA oder > 3 V gegen N |
Konformitäten
Konformitäten | |
---|---|
Elektrische Normen | 2014/35/EU Niederspannungsrichtlinie (LVD) 2014/30/EU Elektromagnetische Verträglichkeit (EMV) EN IEC 61000-6-2:2005 Störfestigkeit für Industriebereiche EN IEC 61000-6-3:2007 + A1: 2011 Störaussendung für Wohnbereich, Geschäfts- und Gewerbebereiche sowie Kleinbetriebe |